The efficiency of induction motor normally fall at the light load and low speed.
The advanced energy-saving mode minimize the loss of induction motor by controlling excitation current belong to the load.
Therefore, this mode increase fan and pump efficiency even in the low speed.
The Energy saved power consumption can be monitored by operation panel or through serial communication data.
Built-in noise filters are ideal for site such as commercial facilities and offices where attention must be paid to peripheral devices.
Compared to filter not integrated models, space and wiring can be saved by incorporating filter in the panel.
Models with built-in EMC noise filter comply with the European EMC Directive as individual inverter units.
New types of compact and space-saving DC reactor is built-in for 200 V class 11 to 45 kW and 400 V 18.5 to 75 kW models.
In addition to reducing harmonics, this reactor limits the input current to 110% of the rated output current, and it has been
designed to be compatible with power supply systems containing transformers, molded-case circuit breakers, and power lines.
Optional DC reactor meets IEC harmonics standards.
Local/Remote mode
You can simply switch between Local and Remote by EASY key. By switching from Remote to Local (Bumpless function),
the operating frequency and status are shifted to Local mode. It is easier for operation and adjustment.
Fire control
Fire control keeps operation with specified speed even if light fault occurs.
Multi-PID function
The PID operation can be changed at direct and inverse proportion by pressure, flow and temperature.
Sleep function (automatic stop function)
Additional energy saving can be realized by stopping at lower limit setting
Low torque detection function
Low torque detection can notice a broken belt of AHU or low load to avoid pump trouble.
PTC thermistor input
This function is used to protect motor from overheating using the signal of PTC built-in motor.
In the Quick mode, pressing the EASY key on the panel allows you to operate the inverter by eight basic parameters.
When setting each functions, press the EASY key to switch to the standard mode by one-touch operation. In this mode, you can access
all parameters.
You can customize the Quick mode display, maximum of 32target parameters are displayed to suit your specific setup requirements.
You can also use the EASY key as a Local/Remote key to switch between Local and Remote operation, and as a shortcut key to
directly access any specific setup or display screen.
Side-by-side installation
. Side-by-side installation is possible for all VF-PS1 models. You can save and optimize space inside of control panel.
Heat sink can be installed outside of the panel as an option.
Removable control terminal board
. A removable terminal board allows you to use the control wiring when replacing the inverter, which also makes
maintenance easier.
ON/OFF control of cooling fan
. Temperature-based cooling fan ON/OFF control reduces sound noise, saves energy, and extends the cooling fan's life.
Monitoring of serviceable service parts/alarm output
. The expected replacement cycle of main circuit capacitors, capacitors on control board, and cooling fan is monitored.
And alarm is raise when the cycle is reached to the expected replacement time
Communications and Network
RS-485 communications
RS-485 communications is equipped as standard. Modbus-RTU protocol and TOSHIBA protocol is also supported.
Network options
DeviceNet®(*1), PROFIBUS, CC-Link(*1), LONWORKS®(*1), BACnet®(*1), Metasys®N2(*1) and APOGEE®FLN(*1) are also available.
Data tracing
The PCM001Z communication software allows you to edit, monitor, and trace parameter data on a PC, enabling easier data management from inverter

*1 DeviceNet is a registered trademarks of ODVA (Open DeviceNet Vendor Association). CC-Link is a registered trademarks of
Mitsubishi Electric Corporation. LONWORKS is a registered trademark of Echelon Corporation. BACnet is a registered trademark of
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Incorporated. Metasys N2 is a registered trademark of
Johnson Controls, Incorporated. APOGEE FLN is a registered trademark of Siemens Building Technologies, Incorporated.
Customizing by "My Function" with Toshiba VF-PS1 inverter

Using "My function", you can create programs up to 28 steps. This achieves logic operations and internal data operations.
Parameters can also be set by analog input and minimum-peak hold of analog outputs.
For example:
(Ex.1) Inverter is automatically switched to commercial operation without external sequence when the inverter is tripped.
(Ex.2) A signal is output when torque reaches 120% and frequency is 5 Hz.
(Ex.3) "Forward rotation operation," "preset-speed operation frequency 3"and "No.2 acceleration/deceleration"are
simultaneously turned ON by input on a single terminal.
(Ex.4) The acceleration/deceleration time is changed dynamically by a voltage within the range 0 to 10 V.

LCD Remote Keypad OptionLCD Remote Keypad Option

This panel indicates 8-line of 23 letters and can be used for simple setup and monitoring by selection of parameters using the jog dial. Type:RKP004Z
LED Remote Keypad Option

20 mm LEDs, ensure outstanding visibility even in the darkness. It is designed to be mounted on the panels as extension display or remote keypad.
In addition, parameter copy and storing function is also available Type:RKP002Z
Expanded Terminal Block Option, Fieldbus Option

I/O terminal block can be added for more complicated operation and wide range of systems:
. Contact inputs (4) . Contact outputs (2)
. Analog inputs (2) . Analog outputs (2)
. PTC input (1) . Relay output (1 circuit)
. Pulse train input (1)
Type:ETB003Z, ETB004Z

Main fieldbuses as built-in option card are supported for space saving and centralized control systems.
. DeviceNet® . PROFIBUS . CC-Link
Type:DEV002Z Type:PDP002Z Type:CCL001Z
. LONWORKS® . BAC net® . Metasys®N2
Type:LIU006Z Type:BCN001Z Type:MTS001Z
. APOGEE®FLN
Type:APG001Z
Control system: Sinusoidal PWM control

Output voltage adjustment: Main circuit voltage feedback control. (Switchable between  adjustment/fix/control off)

Output frequency range: Setting between 0.01 to 500Hz. Default max. frequency is set to 0.01 to 60Hz.
                                    Maximum frequency adjustment (30 to 500Hz)

Minimum setting steps of frequency: 0.01Hz: operation panel input (60Hz base),
                                                     0.02Hz: analog input (60Hz base, 11 bit/0 to 10Vdc)

Frequency accuracy:  Within ±0.2% (25°C±10°C): analog input ±0.01% (25°C±10°C): digital input

Voltage/frequency characteristics: V/f constant, square reduction torque control, automatic torque boost, vector calculation control,
                                                  base frequency adjustment 1 and 2 (25 to 500Hz), V/F 5-point arbitrary setting,
                                                  torque boost adjustment (0 to 30%), start frequency adjustment (0 to 10Hz), stop frequency adjustment (0 to 30Hz)

Frequency setting signal :  3kΩ potentiometer (possible to connect to 1 to 10kΩ-rated potentiometer)
                                       0 to 10Vdc (input impedance Zin: 30kΩ)
                                       0 to ±10Vdc (Zin: 22kΩ)
                                       4 to 20mAdc (Zin:242Ω)

Terminal board base frequency: The characteristic can be set arbitrarily by two-point setting. Compliant with 6 types of input;
                                               analog input (RR, VI/II, RX, RX2), pulse input and binary/BCD input
                                              (*RX2, binary/BCD                                               input: optional)

Frequency jump:  3 places. Setting of jump frequency and width.

Upper and lower limit frequencies: Upper limit frequency: 0 to max. frequency, lower limit frequency:
                                                   0 to upper limit frequency

PWM carrier frequency :  200V-45kW or less, adjustable between 1.0 to 16kHz for 400V-75kW or less200V-55kW or less,
                                    adjustable between 2.5 to 8kHz for 400V-90kW or more

PID control:         Adjustment of proportional gain, integral time, differential time and delay filter

DC braking:         Adjustment of braking start frequency (0 to 120Hz), braking (0 to 100%) and braking time (0 to 10 sec.).
                        With emergency stop braking function and motor shaft fix control function.

Forward run/reverse run *Note 1): With F-CC closed to forward run, with R-CC closed to reverse run, with both closed to reverse run.
                                                  With ST-CC opened to coast stop. Emergency stop by panel operation or terminal board.

Jog run *Note 1):    
Jog mode, if selected, allows jog operation from the operation panel
                             Jog run operation by terminal board is possible by setting the parameters.

Preset speed operation *Note 1):   By changing the combination of open/close between S1, S2, S3, RR/S4-CC, set frequency + 15-speed operation.
                                                  Selectable between acceleration/deceleration time, torque limit and V/f by set frequency.

Retry:   Capable of restarting after a check of the main circuit elements in case the protective function is activated.
            Max. 10 times selectable arbitrarily. Waiting time adjustment (0 to 10 sec.)

Soft stall : Automatic load reduction control at overloading. (Default: OFF)

Cooling fan ON/OFF : The cooling fan will be stopped automatically to assure long life when unnecessary.

Operation panel key operation ON/OFF control :
Key prohibition selectable between Stop key only, Mode key only, etc.
                                                                     All key operations can be prohibited.

Regenerative power ride-through control:
Possible to keep the motor running using its regenerative energy in case of a momentary power failure.
                                                            (Default: OFF)

Auto-restart operation:
Possible to restart the motor in coasting in accordance with its speed and direction. (Default: OFF)

Commercial inverter switching: Possible to switch operation by commercial power source or inverter

Drooping function:
When two or more inverters are used to operate a single load, this function prevents load from
                           concentrating on one inverter due to unbalance.

Override function: External input signal adjustment is possible to the operation frequency command value.

Protective function: Stall prevention, current limit, overcurrent, overvoltage, short circuit on the load side, ground fault on the load side (Note 5),
                              undervoltage, momentary power failure (15ms or more),non-stop control at momentary power failure, overload protection,
                              arm overload at starting, overcurrent on the load side at starting, overcurrent and overload at dynamic braking resistance,
                              fin overheat, emergency stop

Electronic thermal characteristic: Switchable between standard motor/constant torque VF motor, adjustment of overload protection and stall prevention level.
Reset:
Reset by 1a contact closed (or 1b contact opened), or by operation panel. Or power source OFF/ON.
          This function is also used to save and clear trip records.

4-digit and 7-segment LED:
Alarms: Stall prevention during operation, overload limit, overload, undervoltage on power source side,
            DC circuit undervoltage, setting error, in retry, upper limit, lower limit.

Causes of failures:
Overcurrent, overvoltage, fin overheat, short circuit on the load side, ground fault on the load side, inverter overload,
                           arm overcurrent at starting, overcurrent on the load side at starting,
                           EEPROM error, RAM error, ROM error, transmission error, (dynamic braking resistor overcurrent/overload), (emergency stop),
                          (undervoltage), (low current), (overtorque), (motor overload), (output phase failure) The items in the parentheses are selectable.

Monitoring function: Operation frequency, operation frequency command, forward run/reverse run, output current, DC voltage, output voltage,
                              compensated frequency, terminal board input/output information, CPU version, control EEPROM version, past trip history,
                              cumulative operation time, speed feedback, torque, torque command, torque current, exiting current,
                              PID feedback value, motor overload factor, inverter overload factor, PBR overload factor, PVBR load factor, input power,
                              output power, peak output current, peak DC voltage, Motor counter pseudo PG, position pulse, RR input, VI/II input, RX input,
                              RX2 input, FM output, AM output, meter adjustment fix output, flash memory version, main circuit
                              EEPROM version, types of connection option, previous default setting, previous automatic control (AU2)

Free unit display: Display of optional units other than output frequency (motor speed, line speed, etc), current ampere/% switch, voltage volt/% switch

Charge display: 
Displays main circuit capacitor charging.

User default setting: User parameter settings can be saved as default settings. Allows to reset the parameters to the user-defined parameter settings.

Automatic edit function: Searches automatically parameters that are different from the standard default setting parameters.
                                    Easy to find changed parameters.
Input/output terminal input function: Possible to select positive logic or negative logic with programmable input/output terminal function menu.
                                                      Note 1: Note 2: (Default setting: positive logic)
Power Removal safety, function: Built-in Power Removal safety function which complies with EN954-1 category 3 and IEC/EN61508-1 SIL2.
Sink/source switching: Possible to switch between minus common (CC) and plus common (P24) for control terminal. (Default setting: minus common (CC))
Failure detection signal:1c contact output (250Vac-2A-cosØ=1, 250Vac-1A-cosØ=0.4, 30Vdc-1A)
Low speed/speed reach signal output Note 2): Open collector output (24Vdc, max. 50mA, output impedance: 33Ω)
Upper/lower limit frequency signal output Note 2); Open collector output (24Vdc, max. 50mA, output impedance: 33Ω)
Output for frequency meter/output for ammeter Note 3): Analog output. 1mAdc full-scale DC ammeter or 7.7Vdc-1mA voltmeter
Pulse train frequency output: Open collector output (24Vdc, max. 50mA)
Communication function: RS-485 standard 2-channel equipped (connector: modular 8P)
Operating environments: Indoor use. Altitude: 3000m or less (current reduction necessary if 1000m or more.)
                                     Place not exposed to direct sunlight and free of corrosive and explosive gases.
Ambient temperature: -10 to +60°C (Remove the upper cover if 40°C or more, max. 60°C) Note 4:
Vibration: 5.9m/s2{0.6G} or less (10 to 55Hz) (Compliant with JIS C0040)
Storage temperature: -25 to +70°C
Relative humidity:
20 to 93% (free from condensation)
* Toshiba VF-PS1  User manual

* Toshiba VF-PS1 IP54 model user manual

* Toshiba VF-PS1 690V input model User manual

* Precautions of using 4-20mA input signal
* RS485 Communicating manual
* PID control fucntion
* My function
* Current and speed control gain adjustment method
* Commercial/Inverter switching
* DC link connection
* ATEX guide
* Safety function manual
* USB-to-Serial Conversion Unit function USB001Z
* DeviceNet® function DEV002Z
* PROFIBUS DP® function PDP002Z
* CC-LINK® function CCL001Z1
* CC-LINK® function CCL001Z
* LONWORKS® function LIU006Z
* Metasys® N2 function MTS001Z
* BACnet® function BCN001Z
* APOGEE® function APG001Z
* EtherNet/IPTM function IPE001Z
* Modbus TCP function MBE001Z

* Optional Control Power Supply Backup CPS002Z
* PG feedback board option VEC004Z ~ VEC007Z
* Expansion IO Card Option 1ETB003Z
* Expansion IO Card Option 2ETB004Z
* Remote Keypad RKP002Z
* LCD Remote Keypad RKP004Z
* USB-to-Serial Conversion Unit USB001Z
* PROFIBUS DP® option PDP002Z
                         [Notice]
* DeviceNet® option DEV002Z
                         [Notice]
* CC-LINK® Option CCL001Z1
* CC-LINK® Option CCL001Z
* LONWORKS® option LIU006Z
* LONWORKS® option (Plug-in)LIS006Z
* Metasys® N2 option MTS001Z
* BACnet® option BCN001Z
* APOGEE® option APG001Z
* EtherNet/IPTM Option IPE001Z
* Modbus TCP Option MBE001Z
* Braking unit PB7-4200K, 4400K

* Parameter List for VFPS1 (V612~V620)
* Parameter List for VFPS1 (V650/V652)
* Parameter List for VFPS1 (V654)
VF-PS1  toshiba ac drive