Special function block for Mitsubishi plc
MELSEC Special function block for mitsubishi plc
    Extension I/O Units: 32 (16/16) and 48 (24/24) I/O
    Expansion I/O Units:
        8 Inputs 24V Sink/Source, 120VAC, or TTL
        16 Inputs 24V Sink/Source
        4 Transistor (Sink) or Triac Outputs
        8 Relay, Transistor (Sink or Source), or Triac Outputs
        16 Relay, Transistor (Sink or Source), or Triac Outputs
        4 Inputs Sink/Source plus 4 Relay Outputs
    Special Function Units:
        High Speed Counter - 50 kHz
        Pulse Positioning Module
        Analog Output
            2 and 4 channel modules
            Voltage or Current selectable
            Digital Calibration with Custom Ranging
            12 bit resolution
        Analog Input
            4 channel module
            Voltage or Current selectable
            Digital Calibration with Custom Ranging
            12 bit resolution
        Thermocouple Input
            4 channel module
            Channels Individually J or K selectable
            12 bit resolution
            Internal Readings in Deg. C and F
        RTD Input
            2 channel module
            Uses 100 Ohm Sensors
            12 bit resolution
            Internal Readings in Deg. C and F
        Potentiometer Input
            Module has 8 user-adjustable potentiometers
            Can be used for manual timer setup
            8 bit resolution
    Serial Communications:
        RS-232 adapter provides connection to printers,
scales, remote computers, or other controllers.
        RS-485 adapter adds multi-drop
FX series networking capabilities as well.
        Fiber-optic link adapter allows
data exchange between two FX PLC units.
Max. 8 special function blocks per system.
Check the loading on the 5V bus. Consumption values for special
function blocks can be found in table1. 5.For maximum available
current see the table below . Check the
loading on the 24V DC service supply. Look up the number of
expansion I/O on the tables opposite. Find the residual current.
This can then be used to power sensors etc.
Maximum 256 I/O. Key to 24V DC graphs:
A: Number of additional outputs
B: Number of additional inputs
C: Invalid Configuration
Resistors and inputs connected in parallel;
Parallel resistance Rp: FX= 15kW, FX2C= 18kW. If resistance Rp is
less than the stated value, then add Rb. See equation 1 for Rb
calculation. Alternatively; Current leakage:
FX=1.5mA;FX2C=1mA. If the current leakage is greater than the
stated value, then
add Rb.See equation 2 for Rb calculation.
FX-2AD-PT  PT100 probe interface
FX-4AD-TC  Thermo-couple interface
FX-1HC  High speed counter
FX-1PG-E  Pulse output
FX-16NP/NT  Net-mini interface
FX-16NP/NT-S3  Net-mini-S3 interface
FX-4AD  Analog to digital converter
FX-2DA  Digital to analog converter