FX2-40AP, Parallel FX communication
user manual / hand book
Communication module
FX2-40AP
Special Function Block,
FX2-40AP
,
Parallel FX communication
(wire link).
FX2- 40AW,
Parallel FX communication
(fiberoptic link).
FX2-40AP  :
Parallel link adapter-fiber optic connectors two fx or fx2c plc
FX2-40AP,Parallel link adapter-fiber optic connectors two fx or fx2c plc
*** Data exchange by request from computer
Specified data can be exchanged by sending a request command from the computer to the PC. Except for
few functions (global function, on-demand function), the program for data link is not needed at the PC side.
** Batch read / write of all devices (word unit, bit unit) of PC is possible. By reading out the content of each
device of the PC, the operating state can be monitored, or the data can be acquired and analyzed. Besides,
by writing data into each device, production control and production direction can be effected.
** Remote run / stop of PC is possible. A stopped PC can be started and stopped again from the computer,
and therefore the PCs are remote controlled.
** A batch instruction can be issued to all PCs. When one computer and plural PCs are connected, a specific
device (special auxiliary relay M8126) can be turned on or off from the computer to all PCs on the circuit.
This function is called the global function. This special auxiliary relay M8126 is an exclusive device for
global function.
*** Data exchange by request from PC
If transmission of emergency data from the PC to the computer is necessary, the PC issues a send request
to interrupt in the computer. This function is called on-demand function, and is enabled only when the
system is composed of one computer and one PC.
     Extension I/O Units: 32 (16/16) and 48 (24/24) I/O
   Expansion I/O Units:
8 Inputs 24V Sink/Source, 120VAC, or TTL
16 Inputs 24V Sink/Source
4 Transistor (Sink) or Triac Outputs
8 Relay, Transistor (Sink or Source), or Triac Outputs
16 Relay, Transistor (Sink or Source), or Triac Outputs
4 Inputs Sink/Source plus 4 Relay Outputs

    Special Function Units:
High Speed Counter - 50 kHz
Pulse Positioning Module

Analog Output
    2 and 4 channel modules
    Voltage or Current selectable
    Digital Calibration with Custom Ranging
    12 bit resolution

Analog Input
    4 channel module
    Voltage or Current selectable
    Digital Calibration with Custom Ranging
    12 bit resolution

Thermocouple Input
    4 channel module
    Channels Individually J or K selectable
    12 bit resolution
    Internal Readings in Deg. C and F
RTD Input
 
  2 channel module
    Uses 100 Ohm Sensors
    12 bit resolution
    Internal Readings in Deg. C and F

Potentiometer Input
    Module has 8 user-adjustable potentiometers
    Can be used for manual timer setup
    8 bit resolution

    Serial Communications:
RS-232 adapter provides connection to printers,
scales, remote computers, or other controllers.
RS-485 adapter adds multi-drop FX series
networking capabilities as well.
Fiber-optic link adapter allows data exchange
between two FX PLC units.
FX COMMUNICATION (RS-232C, RS-485, RS-422) (pdf)
FX-8AV  FX-8AV : Potentiometer input unit
(8 potentiometers; values can be read in to PLC program)
FX2-40AP  Parallel link adapter-fiber optic connectors two fx or fx2c plc
FX2-40AW  For communication between two FX-systems
FX-232ADP  The FX-232ADP type RS232C adapter (heremafter called 232ADP)
IS connected to the FX(V3 07 or later),
FX-485ADP  The adapter for FX-485ADP RS485 or the adapter
for FX0N-485ADP RS485
(both called 485ADP hereinafter) is designed to link the data between
PC and computer by using 485PC-IF.
WHAT IS SERIAL COMMUNICATION?