FX-8AV
Analog Setpoint Adapters FX-8AV and FX-8AV-BD
The FX-8AV-BD analog setpoint adapters
enable the
user to set 8 analog setpoint values.
The analog values of the potentiometers are read into
the controller and used as default
setpoint values for timers, counters and data registers
by the user’s PLC programs.
Setpoint value polling and the definition of the
potentiometer scales are performed in
the PLC program using the dedicated instructions
VRRD/VRSC (FNC85/86).
The FX-8AV-BD analog setpoint adapters are installed
in the expansion slot of the
FX1S/FX1N/ FX3G CPU. No additional power supply is
required for operation.
     Extension I/O Units: 32 (16/16) and 48 (24/24) I/O
   Expansion I/O Units:
8 Inputs 24V Sink/Source, 120VAC, or TTL
16 Inputs 24V Sink/Source
4 Transistor (Sink) or Triac Outputs
8 Relay, Transistor (Sink or Source), or Triac Outputs
16 Relay, Transistor (Sink or Source), or Triac Outputs
4 Inputs Sink/Source plus 4 Relay Outputs
    Special Function Units:
High Speed Counter - 50 kHz
Pulse Positioning Module
Analog Output
    2 and 4 channel modules
    Voltage or Current selectable
    Digital Calibration with Custom Ranging
    12 bit resolution
Analog Input
    4 channel module
    Voltage or Current selectable
    Digital Calibration with Custom Ranging
    12 bit resolution
Thermocouple Input
    4 channel module
    Channels Individually J or K selectable
    12 bit resolution
    Internal Readings in Deg. C and F
FX-8AV  FX-8AV : Potentiometer input unit
(8 potentiometers; values can be read in to PLC program)
RTD Input
    2 channel module
    Uses 100 Ohm Sensors
    12 bit resolution
    Internal Readings in Deg. C and F
Potentiometer Input
    Module has 8 user-adjustable potentiometers
    Can be used for manual timer setup
    8 bit resolution
    Serial Communications:
RS-232 adapter provides connection to printers,
scales, remote computers, or other controllers.
RS-485 adapter adds multi-drop FX series
networking capabilities as well.
Fiber-optic link adapter allows data exchange
between two FX PLC units.
FX-8AV  FX-8AV : Potentiometer input unit
(8 potentiometers; values can be read in to PLC program)
FX2-40AP  Parallel link adapter-fiber optic connectors two fx or fx2c plc
FX2-40AW  For communication between two FX-systems
FX-232ADP  The FX-232ADP type RS232C adapter (heremafter called 232ADP)
IS connected to the FX(V3 07 or later),
FX-485ADP  The adapter for FX-485ADP RS485 or the adapter
for FX0N-485ADP RS485
(both called 485ADP hereinafter) is designed to link the data between
PC and computer by using 485PC-IF.
WHAT IS SERIAL COMMUNICATION?