inverter,plc,drive,control
FX - FX0 - FX1S -FX1N - FX2N -FX2NC - FX3G - FX3U -FX3UC -( Q plc - AlfaHMI-PANEL AC DRIVES  Plc Cable Mitsubishi PLC software
programmable logic control
Mitsubishi Melsec FX series Expansion-modules - special functions block :
FX-2PIF,FX-10DU-E,FX-20DU-E,FX-25DU-E,FX-30DU-E,FX-40DU-ES
FX-40DU-TK-ES,FX-50DU-TK,FX-50DU-TKS,FX0N-40ET-DSS FX0N-40ER-ES/UL
FX0N-40ER-DS,FX0N-8ER-ES/UL,FX0N-8EYR-ES/UL,FX0N-8EYT-ESS/UL
FX0N-8EX-ES/UL,FX0N-16EX-ES/UL,FX0N-16EYR-ES/UL,FX0N-8EX-UA1/UL,
FX-RTC FX-EEPROM-4,FX-EEPROM-4C,FX-232AW/AWC,FX-EEPROM-8C,FX-2PIF
FX0N-232ADP,FX-EPROM-8,FX0N-485ADP,FX-232AW/AWC,FX-10P-E,FX-20P-E,
GP-80 HGP + GP80FXE-KIT,A6GPP/PHP + FX-A6GPP-E-KIT
THE FX SERIES OF PROGRAMMABLE CONTROLLER.pdf
FX0-FX0N SERIES PROGRAMMABLE CONTROLLERS HARDWARE MANUAL.pdf
MELSEC FX0S,FX0N,FX2N TECHNICAL CATALOG.pdf
FX0N-60MT-DSS Earthing/Grounding
For grounding, use at least 2mm2 (AWG14) cable. Ground resistance must be less than 100 W (Class 3). The PC’s ground
must not be shared with that of the power circuits. While grounding is recommended, if it is not possible, the PC will still operate
correctly without it. Ground terminal: All ground terminals should be linked with 2mm2 (AWG14) cable. The linked terminals
should all be connected to a single earth point.
MITSUBISHI MELSEC FX0,FX0S,FX0N PLC,USER MANUAL / HAND BOOK
The MELSEC FX0N-60MT-DSS PLC Series
Description
Small-scale PLC offering excellent value for money.
** Small , ** Fast , ** Universal,** Modular expansion capability
The ability to combine the compact base units with small, modular
expansion units and compact I/O expansion unitsmakes the
FX0N enormously flexible, giving you a highly economical
combination of the cost
benefits of compact systems with the versatile expansion
capabilities ofmodular systems.
MITSUBISHI MELSEC FX0N-60MT-DSS FEATURES

INPUT:
36 DIGIT
OUTPUT:
24 SIGITAL
OUTPUT TYPES:TRANSISTOR
SUPPLY VOLTAGE:24VDC
INTERNAL RELAYS: 512 (128 STORED EEPROM)
DATA REGISTERS: 256 (128 STORED EEPROM)
TIMERS: 64
STATES:
128
COUNTERS:
32 (16 STORED IN EEPROM)
HIGH SPEED COUNTERS: MAX. 4 AND 32 BIT
OPERATION PROCESSING TIME:
BASIC INSTRUCTION:
1.6 TO 3,6 MS
APPLIED INSTR:10-100 MS.
NUMBER OF INSTRUCTIONS: 20 SEQUENCE,42 APPL.
PROGRAM SIZE: 2000 STEPS ALL STORED EEPROM
MEASURES: 130*90*87
FX0N-60MT-DSS System structure
** Base unit with full PLC functionality
** Integrated power supply unit
** CPU
** Maintenance-free EEPROM memory
** Integrated digital inputs and outputs
** Expansion units for adapting the controller
system to the required I/O ranges and functionality
** Configurable as a slave station in peer-topeer
and 1:n networks (version 2.00 and above)
** User-friendly programming systems,including
hand-held programming units,
IEC 1131.3-compatible programming
software and MMIs
FX0N-60MT-DSS
Themodular design of the FX0N-60MT-DSS series makes it extremely
flexible, enabling it to be used for a very broad range of applications.
You can configure tailor-made systems by combiningmodules froma variety of
different categories (see figure).Allmodules are electrically isolated from their
environment with optocouplers for maximum reliability.
DIGITAL INPUTS/OUTPUTS,ANALOG
INPUTS/OUTPUTS,POSITIONING MODULES,
COMMUNICATIONS MODULES CPU
FX0N-60MT-DSS Analog I/Omodules
For processing current/voltage signals and temperature registration with 
connection option for Pt100 resistance thermometers andthermocouples.
FX0N-60MT-DSS Digital I/Omodules For a variety of signal levels
with relay or transistor switches.
FX0N-60MT-DSS Positioningmodules
High-speed counter modules with support for the connection of incremental
rotary transducers and positioningmodules for
servo and steppingmotor drives.
FX0N-60MT-DSS Communications modules
Interfacemodules with RS-232/RS-422/RS-485 interfaces
for the connection of peripherals and PLC–PLC links. Network
modules for Profibus, GSMand for the configuration of proprietary
Mitsubishi networks
FX0N-60MT-DSS Accessories
Equipment features
Base units are available in a number of versions with different power supply and output type configurations.
You can choose between units with 230 V AC or 24 V DC power supplies and relay or transistor outputs.
All the base unit versions have the same basic CPU and performance specifications.


High-speed inputs for fast counting taskswith counting
frequencies of up to 5 kHz and
interrupt processing capabilities.
Integrated RUN/STOP switch and two
analog potentiometers for setpoint value entry.
The base units have integrated,
maintenance-free EEPROM usermemory for up to 2000
PLC programsteps with a backup battery to protect
memory contents against power failures. You can also configure password protection to prevent
unauthorised access to your programs.
Integrated pulse outputs
for frequencies from10 to 2000Hz for controlling
steppingmotors and outputting pulse-width
modulated signals.
External EPROMor EEPROM memory cassettes for PLC program storage.
These memory cassettes are also available in versions with a real-time clock. 18
The base units can be expanded for up to 128 I/Os with both
modular and compact expansion units.